Configure the settings for the local alarms.
Parameter Description
Alarm-in Port Select the channel number.
Alarm Name Enter the customized alarm name.
Enable Enable or disable the local alarm function.
Device Type
In the Device Type list, select NO or select NC as the voltage output type.
Schedule
Click Setting to display setting interface.
Define a period during which the motion detection is active. For details, see
"Setting Motion Detection Period" section in "5.10.4.1 Configuring Motion
Detection Settings."
Anti-Dither Configure the time period from end of event detection to the stop of alarm.
Alarm-out Port
Click Setting to display setting interface.
Local Alarm: Enable alarm activation through the alarm devices
connected to the selected output port.
Extension Alarm: Enable alarm activation through the connected alarm
box.
Wireless Siren: Enable alarm activation through devices connected by
USB gateway or camera gateway.
Post-Alarm
Set a length of time for the Device to delay turning off alarm after the
external alarm is cancelled. The value ranges from 0 seconds to 300 seconds,
and the default value is 10 seconds.
Show Message
Select the Show Message check box to enable a pop-up message in your
local host PC.
Report Alarm
Select the Report Alarm check box to enable the system to upload the
alarm signal to the network (including alarm center) when an alarm event
occurs.