User Manual

Drag an end to the desired place to adjust the length and angle of the line. And drag the
line to adjust the location.
6. Configure the parameters for each defense region separately.
Direction: Select the detection direction in the dropdown list, there are A<->B, A->B and
B->A selectable.
Sensitivity: The value of the sensitivity defines the size of the object which can trigger the
alarm, when the sensitivity is high, a very small object can trigger the alarm.
Detection Target: You can select human, vehicle, or all (human &vehicle) as the detection
target. If Human is selected, only human beings will be identified as detection objects and
as well as Vehicle.
Note:
For network cameras, regions can be set simultaneously before clicking Save button. For
speed domes, you need to set one region and save it, then continue to set and save the next
region.
7. Click tab to enter the arming schedule setting interface. The time schedule
configuration is the same as the settings of the arming schedule for motion detection. Refer
to Section 5.2.1 Configuring Motion Detection for more details.
8. Click tab to select the linkage method taken for the line crossing detection,
Notify Surveillance Center, Send Email, Upload to FTP/Memory Card/NAS, Trigger Alarm
Output, Trigger Recording, Smart Tracking, White Light Flashing, and Audible Warning are
selectable.
For speed dome, you can also choose to link smart tracking. Smart Tracking should be
configured in advance.
For certain models, White Light Flashing and Audible Warning are supported. Refer to
Section 5.2.1 Configuring Motion Detection for detailed configuration.
9. Click to save the settings.
5.3.5 Configuring Region Entrance Detection
Note:
The function varied depending on different speed domes.
Purpose:
Region entrance detection function detects people, vehicle or other objects which enter a pre-
defined virtual region from the outside place, and some certain actions can be taken when the
alarm is triggered.
Steps:
1. Enter the Region Entrance Detection settings interface:
Configuration> Event > Smart Event> Region Entrance Detection
Formatted: Font: Not Bold, Not Italic