Operation Manual
Table Of Contents
- Foreword
- 1 Product Introduction
- 2 Basic Settings
- 3 Daily Operation
- 3.1 Live
- 3.2 PTZ
- 3.2.1 Bullet Cameras
- 3.2.2 Speed Dome Cameras & Pan Tilt Cameras
- 3.2.2.1 Configuring Protocol
- 3.2.2.2 Configuring PTZ Functions
- 3.2.2.2.1 Configuring Preset
- 3.2.2.2.2 Configuring Tour
- 3.2.2.2.3 Configuring Scan
- 3.2.2.2.4 Configuring Pattern
- 3.2.2.2.5 Configuring Pan
- 3.2.2.2.6 Configuring PTZ Speed
- 3.2.2.2.7 Configuring Idle Motion
- 3.2.2.2.8 Configuring Power Up
- 3.2.2.2.9 Configuring Time Task
- 3.2.2.2.10 Restarting PTZ Manually
- 3.2.2.2.11 Restoring PTZ to the Default Settings
- 3.2.2.3 Operating PTZ
- 3.2.2.4 Configuring Preset Backup
- 3.3 Playback
- 3.4 Reports
- 3.5 Alarm
- 4 Setting
- 4.1 Configuring Camera
- 4.1.1 Configuring Lens
- 4.1.2 Configuring Video Parameters
- 4.1.3 Configuring Audio Parameters
- 4.2 Configuring Network
- 4.3 Peripheral
- 4.4 Smart Thermal
- 4.5 Event
- 4.6 Temperature Measuring Settings
- 4.7 Storage Management
- 4.8 System Management
- 4.1 Configuring Camera
- 5 System Maintenance
- 6 Additional Accessing Methods
- Appendix 1 Cybersecurity Recommendations
83
Timing: You can configure the Interval Time and Period.
1. Interval Time: Interval from the point when the wiper starts to the point when
the wiper stops.
2. Period: Time when the wiper works.
3. Click Save.
Manual: Turn on and off the wiper manually.
1. Interval Time: Interval from the point when the wiper starts to the point when
the wiper stops.
2. Click Start to get the wiper work in the interval time you have just set, and if you
think the wiper has done enough work, click Stop to end it; Click Once to get the
wiper work for one round.
4.3.3 Configuring Fan
Select Setting > Peripheral > Fan.
The Fan interface is displayed. See Figure 4-40.
Fan
Configure fan’s running mode:
Auto: Fan works automatically. Click Save.
Manual: Start your fan manually. Select the Enable check box and click Save.
4.3.4 Configuring Heater
Select Setting > Peripheral > Heater.
The Heater interface is displayed. See Figure 4-41.
Heater
Configure heater’s running mode:
Auto: Select Start Tem and Stop Tem as the temperature range for heater to start, and
click Save. When the sensor temperature is in the range, heater works automatically.