Operation Manual

Table Of Contents
125
See Figure 4-69.
Rule adding
2) Double-click the rule you have just added to select monitoring items and modify the
monitoring name.
3) Draw your rules.
Select Monitoring Items as Spot, and you can click a position on the surveillance
image and a spot is formed.
Select Monitoring Items as Line, Rectangle or Ellipse, and you can hold the left
mouse button to draw rules you need on the surveillance image.
Select Monitoring Items as Polygon, and you can hold the left mouse button to
draw rules you need on the surveillance image. Right-click to end your drawing.
Select a rule you have drawn and click Redraw Rule. Then you can delete the rule and
draw a new one.
4) Select the Open Local Config check box and configure parameters. See Table 4-39.
Table 4-39 Parameter description of local configuration
Parameters Description
Target Radiation
Coefficient
Radiation coefficient of targets that are shot by this Camera. Ranges
from 0.5 1.
Target Distance
Distance from the camera to targets that are shot. Ranges from 0m
10000m.
Target Reflection
Temperature
Temperature of targets that are shot by this Camera. Ranges from
-50 °C to 327.7 °C.
5) Enable the Relay-out check box and configure its parameters. See Table 4-40.