Installation Guide

QUICK INSTALL GUIDE
Installing the Enphase Q Aggregator
To install the Enphase Q Aggregator, read and follow all warnings and instructions in this Guide and in the Enphase IQ System Installation and Operation
Manual at enphase.com/support. If you do not fully understand any of the concepts, terminology, or hazards outlined in these instructions, refer installation to
a qualied electrician or installer. These instructions are not meant to be a complete explanation of a renewable energy system. All installations must comply
with national and local electrical codes. Professional installation is recommended.
IMPORTANT: Enphase IQ Envoy and IQ 6 and IQ 6+ Micros do not communicate with, and should not be used with, previous generation Enphase Microinvert-
ers and Envoys. Always use the Q Aggregator and other Q accessories with IQ 6 and/or IQ 6+ Microinverters.
PREPARATION
A ) Check the box for the following items:
Enphase Q Aggregator
One bulkhead connector cap (Q-BA-CAP). You may need to order an
extra cap if you connect only one branch circuit to the aggregator.
Quick Install Guide (this document)
B ) Check that you have these required items:
Enphase Q Aggregator(s) for multiple branch arrays
Drill with an appropriately sized hole saw
Screwdrivers
Wire stripping tool
Torque wrench and sockets for mounting hardware
75° to 90° C-rated conductors for connections between the Q
Aggregator and main PV breaker
Enphase disconnect tool
C ) Protect your system with lightning and/or surge suppression devices at
the sub or main panel.
D ) Protect the Q Aggregator with a maximum 60-amp over-current
protection device (OCPD).
E ) Size the AC wire gauge to account for voltage rise. Select the correct
wire size based on OCPD size and on the distance from the beginning
of the Enphase Q Cable to the breaker in the load center. Design for
a voltage rise total of less than 2% for the sections from the Enphase
Q Cable to the breaker in the load center. Refer to the Voltage Rise
Technical Brief at
enphase.com/support for more information.
Best practice: Use a Q Aggregator and Enphase Q Field Wireable
Connectors to center-feed each branch circuit to minimize voltage rise
in a fully-populated branch.
F ) Plan to install the Q Aggregator in a location that will be under the
modules when the array is complete.
AC connector
Enphase
IQ 6 Micro or
IQ 6+ Micro
DC connectors
Enphase Q
Aggregator
AC connections
terminator
Enphase
Q Cable
Cable clips or
tie wraps
Features
Lets you install systems up to 11.5 kW with only two line
conductors and a ground coming from the roof
Usable in any position up to 45 degrees from horizontal
(NEMA 3R, includes drain holes)
The aggregator bracket is ready to install on rail, can be ipped
for roof or block mount installs, and allows you to t conduit
into either or both sides
How It Works
Use the Enphase Q Aggregator to bring together up to three
branches of microinverters, center feed branch connections,
or connect a remote part of the array using Enphase Q Field
Wireable Connectors.
Enphase
disconnect
tool