IQ Load Controller Additional Info
Load and Solar Circuit Control using IQ System Controller Auxiliary Contacts
14 © 2021 Enphase Energy Inc. All rights reserved. December 16, 2021
Automatically shed solar circuit when off-grid
IQ System Controller auxiliary contacts will shed specific PV circuits from the microgrid to ensure that the
solar to storage continuous power ratio is maintained at a safe level.
Mode
MID
PV circuit state
on-grid
MID Closed
Connected
off-grid
MID Open
Disconnected
Table 5: Automatically shed PV circuit when off-grid
Automatically shed PV circuit when off-grid
Figure 11: Automatically shed PV circuit when off-grid - Enable PV shedding
1. Click ‘Configure’ button
2. Check ‘PV Shedding’ to configure the Auxiliary contact for PV Shedding
3. Select the microinverter serial numbers in the PV branch circuit and click ‘Save’