IQ Load Controller Additional Info

Load and Solar Circuit Control using IQ System Controller Auxiliary Contacts
12 © 2021 Enphase Energy Inc. All rights reserved. December 16, 2021
Mode
MID
GID
Load circuit
state
on-grid
Closed
Open
Connected
off-grid
Open
Open
Disconnected
off-grid
Open
Closed
Connected
Table 4: Automatically shed load when off-grid and restore when generator is connected
Figure 9: Generator Mode: Shed load when off-grid and restore when generator is connected
1. In ‘Advanced’ Mode, Select ‘Generatorunder ‘Off Grid Power Source’
2. Check ‘Home owner can override’ – this will let the home owner to access the settings from
Enphase App Home Owner App
3. Press ‘Save’