Technical data
Table Of Contents
- Important Information
- The Enphase Envoy Communications Gateway
- Installation Planning and Preparation
- Install the Envoy
- 1. Find the Envoy Serial Number
- /2. Register the Envoy
- 3. Find a Location for the Envoy
- 4. Connect to the Internet
- 5. Check the Internet Connection
- 6. Install the Modules and Microinverters
- 7. Check the Envoy’s Progress
- 8. Wall Mount the Envoy (Optional)
- 9. Build the Virtual Array
- 10. View System Performance in Enlighten
- Envoy Operation
- Troubleshooting
- Power Line Communication Troubleshooting
- Network Basics and Troubleshooting
- Issue: IP Address Problems
- Issue: LCD Screen Displays “-Web”
- Issue: LCD Screen Displays “Envoy Failure +Web or -Web”
- Issue: LCD Screen Displays "Scanning Inhibited"
- Issue: The Envoy has Good Signal Strength but is Too Far from the Router
- Issue: Wireless Adapter Wi-Fi Problems
- Issue: How Set Up Wi-Fi Without Wi-Fi WPS
- Issue: Internet Traffic is Slower After Installing a Bridge
- DHCP versus Static IP Addressing
- MAC Filtering
- Firewall Settings
- Replacing an Envoy
- Envoy Local Interface
- Technical Data
Envoy Installation and Operation
2014 Enphase Energy Inc. 141-00011 Rev 05
60
Technical Data
Communications Interface
Power line
Enphase proprietary
Ethernet
10/100 auto-sensing, auto-negotiation
USB (one or two ports, depending on
Envoy model)
USB 2.0 interface, auto-sensing, auto-negotiation
Monitoring capacity
Model numbers (SKU) ENV-120-01 and ENV-120-02 can
monitor up to 600 Enphase Microinverters.
Power Requirements
AC outlet
120 VAC, 60 Hz
Power consumption
2.5 watts typical, 7 watts maximum
Mechanical Data
Dimensions (WxHxD)
8.8” x 4.4” x 1.7”
(222.5 mm x 112mm x 43.2mm)
Weight
12 oz (340g)
Ambient temperature range
-40˚C to +65˚C (-40˚ to 149˚F)
Cooling
Natural convection – no fans
Enclosure environmental rating
Indoor - NEMA 1
Features
Standard warranty term
2 years
Compliance
UL 60950-1, EN 60950-1,
CSA22.2 No. 60950-1 and IEC 60950-1,
FCC Part 15 Class B,
CAN ICES-3(B)/NMB-3(B)
Meter accuracy
Envoy metering is qualified as +/- 5% or better.
CSI Eligibility
The Envoy is included in the List of Eligible System
Performance Meters for the CSI program.
API
Production data