Technical data
Page 17 Copyright Enphase Energy Inc. 2009 141-00008 REV 06
- Relocate your Envoy closer to the electrical service-panel (load-center)
as possible. This ensures that the Envoy receives the strongest
possible signal from each microinverter.
- Plug the Envoy into another circuit supporting fewer electronic devices,
as these devices may interfere with communication between the
microinverters and the Envoy.
Remaining minutes and seconds are displayed (“mm:ss” in the example). The
“Devices” counter displays the numbers of devices detected and will ascend
until all devices are detected. The number of devices detected should match
the number of installed microinverters.
After 20 minutes, the communication check times out. If you want to end the
communication check before it times out, press the menu button to activate
the Envoy menu. When the LCD indicates “Disable Communication Check”,
release the menu button.
Restarting the Envoy
If the utility ever fails, or you need to restart the Envoy, just plug it in (if not already
done) and let the Envoy start up again. It will resume operation when power and
internet connection are restored. When it resumes operation, the LCD window
displays the auto-start sequence. The system performs an automatic
communications check. The LCD window alternates between two displays like those
shown in the following:
For information on the “Level” and “Devices” indicators, refer to the descriptions in
“Performing a Communication Check” on page 16. The auto-start sequence continues
for 20 minutes after starting up the Envoy. After this check, normal operation
resumes.
[▌▌▌ ] mm:ss +Web
LEVEL
D
evices: n
192.168.2.140 +Web
2407W 783kWh 25