Performing a Communication Check
If, when you are installing the Envoy, you are unsure of where it should be located
for maximum performance, you may want to install the Envoy in different locations
and check signal strength. A communication check starts automatically after an
Envoy restart. In addition to this automatic check a user-initiated communication
check can be started with the Envoy Menu button or through the administration page
when connected to the Envoy local connection with a computer.
To initiate a communication check:
1. Press and hold the Menu button on Envoy for two seconds to bring up the
Envoy menu on the LCD window. When the LCD window displays: “Enable
Communication Check”, release the Menu button.
The LCD window then indicates:
The Envoy begins a 20 minute communication check to assess the signal
strength between the Envoy and the devices deployed at your site.
2. Until the Envoy begins detecting devices (microinverters), the display reads:
3. When the Envoy begins detecting devices (microinverters), the display reads:
The “LEVEL” indicator in the LCD window may display any number of bars
from zero to five. You can assume that the communication check is
progressing normally and that signal strength is acceptable if two to five bars
are displayed. If fewer than two bars are displayed, you may want to try the
following options:
Comm Check
+
Web
Scanning Devices...
[▌▌▌ ] mm:ss +Web
LEVEL
D
evices:
n
Comm
c
h
eck
e
n
able
d
for 20min
Enable
Communication Check