Technical data
Page 15 Copyright Enphase Energy Inc. 2009 141-00008 REV 06
To select a menu item, release the Menu button when the desired menu
option appears. The menu continues to cycle as long as you are pressing the
Menu button. See the following sections for detailed procedures.
Each microinverter is powered by the photovoltaic module it is connected to,
so device scan or communication check can only be successfully performed
during daylight hours.
Initiating a Scan for New Microinverters
To initiate a scan:
1. Press and hold the Envoy Menu button; after two seconds you will enter the
Envoy menu. Continue holding the Menu button, when the LCD window
displays: “Enable New Device Scan”; release the Menu button.
The LCD window then indicates:
2. The Envoy begins a 30 minute scan, if a longer scan is not already in
progress, to identify all of the microinverters deployed at the premises.
3. Log into the Enphase Enlighten™ web-based monitoring and analysis to view
data on a per microinverter basis (and, hence, a per PV module basis).
4. To disable or cancel a scan, press and hold the Menu button on the front of
the Envoy for two seconds to view the Envoy menu on the LCD. When the
LCD window displays: “Disable New Device Scan”; release the Menu button.
Disable
New Device Scan
Enable
New Device Scan
Disable
Communication Check
Device scan active
for nnd:nnh:nnm