Technical data
Envoy Installation and Operation
Copyright 2012 Enphase Energy 141-00014 Rev 03
47
Where message is displayed:
Description
Home Screen
Inventory Screen
Module added
Description: The Envoy has detected and is now associated to a new
microinverter.
No action is required.
Microinverter
failed to report
Failed to report
Recommended Action: You can ignore occasional instances of this error.
Communications will likely recover on the next reporting cycle.
If communications do not recover immediately, make sure that the Envoy
is plugged in very near to the AC mains. Also, if other devices are sharing
the outlet with the Envoy, remove those devices from the outlet to improve
communication signal strength.
If the Enphase Envoy was recently relocated or if new devices or
appliances were added to the circuit, it is possible that the new situation is
not suitable for power line communication. The Envoy may need to be
relocated to improve signal strength and reduce interfering noise on the
power lines.
To determine the quality of the Envoy’s location for communication, please
run a Communications check by holding down the Envoy’s menu button
until the LCD display reads “Enable Communication Check” and then
release the menu button. The Envoy will then broadcast a signal to the
microinverters. Within 5 minutes, a “Comm Level” indication of 0 to 5 bars
will display on the Envoy LCD display. The Envoy requires a minimum of 3
bars to communicate effectively with the microinverters.
Description: The Envoy reporting this condition is unable to communicate
with the microinverters over the power lines.
If the condition persists: See “Power Line Communication
Troubleshooting” on page 29, or contact your installer, or refer to the
Troubleshooting Guide at http://www.enphase.com/downloads/.
Microinverter
grid
configuration
failed after 5
attempts,
retrying
Description: The attempt to change the grid profile for the microinverters
has failed after five tries. The Envoy will continue to attempt to change the
grid profile.
Recommended Action: No action is required.
Microinverter
grid
configuration
failure cleared
after xx
attempts
Description: A failed attempt to change the grid profile for the
microinverters has cleared. The grid profile was successfully applied.
xx = number of attempts
Recommended Action: No action is required.
Module
Sleeping
Sleeping
Description: The microinverter is off for the night.
Recommended Action: No action is required.
No Grid Profile
No Grid Profile
Recommended Action: Ask the installer to use the Envoy Gateway
interface to select a grid profile for this system. For more information, refer
to “Manage Grid Profile” on page 36
Description: The Envoy has not been set up with a grid profile for the
microinverters.
Over
Temperature
Over Temperature
Description: The microinverter is too hot and is not producing power. This
very rare condition usually clears without intervention.
Recommended Action: No action is required unless the condition
persists. If it persists, contact Enphase Energy customer support.
Power
generation off
by command
Power generation off
by command
Description: The microinverter is not producing power by user command.
This uncommon condition will occur only during isolated troubleshooting
procedures by Enphase personnel.
Recommended Action: No action is required.