Technical data
Envoy Installation and Operation
Copyright 2012 Enphase Energy 141-00011 Rev 03
44
Where message is displayed:
Description
Home Screen
Inventory Screen
Microinverter
grid
configuration
failed after 5
attempts,
retrying
Description:
The attempt to change the grid profile for the microinverters
has failed after five tries. The Envoy will continue to attempt to change the
grid profile. No action is required.
Microinverter
grid
configuration
failure cleared
after xx attempts
Description:
A failed attempt to change the grid profile for the
microinverters has cleared. The grid profile was successfully applied to
the microinverters. No action is required.
xx = number of attempts
Module
Sleeping
Sleeping
Description
: The Microinverter is off for the night.
No action is required.
No Grid Profile No Grid Profile
Recommended Action
: Use the Envoy Gateway web interface to select a
grid profile for this system. For more information refer to “Manage Grid
Profile” on page
29
Description
: The Envoy has not been set up with a grid profile for the
microinverters.
Over
Temperature
Over Temperature
Description
: The microinverter is too hot and is not producing power.
This very rare condition usually clears without intervention. No action is
required unless the condition persists. If it persists, contact Enphase
Energy customer support.
Power
generation off
by command
Power generation off
by command
Description
: The microinverter is not producing power by user command.
This uncommon condition will occur only during isolated troubleshooting
procedures by Enphase personnel. No action is required.
Power On Reset Power On Reset
Description
: The microinverter has powered on after having both AC and
DC disconnected.
No action is required.
Shutdown
Description
: The Envoy has been powered down (unplugged from AC
power).
Restore AC power to the Envoy.
Startup
Description
: The Envoy has been powered back up (plugged back in to
AC power).
No action is required.
Transient Grid
Profile
Transient Grid Profile
Recommended Action
: No action is required. This condition will clear
once the grid profile test is complete.
Description
: This system is currently in test mode.