Technical data

Envoy Installation and Operation
Copyright 2012 Enphase Energy 141-00011 Rev 03
19
The Envoy begins a 30-minute scan (if a longer scan is not already in progress) to
identify all of the microinverters deployed at the site.
3. Use your previously issued username and password to check for the new microinverter
in Enlighten. If you do not have a link to Enlighten, go to
www.enphase.com and click
Enlighten Login. From here you can register (if not already done) and view data on a
per-microinverter basis (and, hence, a per-PV module basis).
4. To disable or cancel a scan, press and hold the Envoy Menu button for two seconds to
view the Envoy menu. When the LCD screen displays: “Disable New Device Scan”,
release the Menu button.
Viewing the Grid Configuration
To view the grid configuration (trip points profile) for the site, do the following.
Note: You cannot change the grid profile using this menu. To change this profile, refer
to
Manage the Grid Profile on page 29.
1. Press and hold the Envoy Menu button; after two seconds the Envoy menu appears.
2. Continue holding the Menu button; when the LCD screen displays “View Grid
Configuration”, release the Menu button.
The LCD screen then reads:
If a grid profile has not been applied, the following screen is displayed:
This indicates that the microinverters are not yet configured with a grid profile.
3. Configure these settings as described in Manage the Grid Profile on page 29. You
can press the menu button to exit this process.
No Grid
Config. Applied
Gathering Grid
Configuration Data
View Grid
Configuration
Disable
New Device Scan