Enclosure Options for the IQ Envoy
Arlington EB1212-BP Enclosure with Back Plate
• Lockable unit dimensions are 12"x12"x4"
• Easily accommodates the addition of a field-
wired receptacle, if needed
• Outdoor rated with hinged door opening
upward, but indoor rated with hinge to side
Orbit 57905 Timer Cabinet
• Back plate included, NEMA3R, lockable
• Approximate dimensions are 11"x10"x5"
• Includes a receptacle pre-installed (not
wired)
• Mounting plate and IQ Envoy must be
removed to install back mounting screws
• Tight wiring space for IQ Envoy with PLC
bridge
Integra H12104H*** Enclosures
• Strong metal or poly backplate options,
NEMA4, lockable
• Approximate dimensions are 10"x12"x5"
• Easily accommodates addition of a field
wired receptacle, if needed
• Manufacturer provides a wide variety of
enclosure options, including mounting tabs,
and vents
Attabox AH12106 Enclosure with BP1210A Back Plate
• Strong metal or poly backplate options, NEMA4, lockable
• Approximate dimensions are 10"x12"x5"
• Easily accommodates the addition of a field wired receptacle, if needed
• Manufacturer provides a wide variety of enclosure options, including mounting tabs, and vents
Cantex 5133714 Enclosure with Cover and Gasket
• NEMA4, PVC electrical enclosure
• Approximate dimensions are 12”x12”x6”
• Requires eight screws to install or remove cover and gasket