Ensemble Communications Kit Manual
Install the Communications Adapter
The kit includes the wireless USB adapter with USB cable (for power and
communications) and tie wraps. To install the adapter adjacent to an
Enphase IQ Envoy or in an Enphase IQ Combiner, do the following:
A ) If installing in an IQ Combiner, open the enclosure door.
B ) Select or locate the installation position for the adapter:
• For IQ Combiner (Model X-IQ-AM1-240-B), place the adapter on
the bottom interior surface of the enclosure, taking care to allow
room for the door to close completely.
• For IQ Combiner 3 and IQ Combiner 3C (Models X-IQ-AM1-240-3
and Model X-IQ-AM1-240-3C), place the adapter on the front side
of the deadfront on the right side (see image to the right).
• For the IQ Combiner+ (Model X-IQ-AM1-240-2), place the adapter
on the front side of the deadfront on the left side.
• For IQ Envoy (Model ENV-IQ-AM1-240), select a mounting location
near the IQ Envoy, so that the USB cable can reach between the IQ
Envoy and the adapter.
C ) Plug the free end of the USB cable into a USB port on the IQ Envoy.
D ) If installing in an IQ Combiner, use the tie wraps and adhesive patch
to hold the adapter in place in the designated location. Either weave
the tie wraps through the openings in the dead front, or use the
adhesive patch to hold the adapter in place. You can use both, if
needed.
E ) If installing the adapter with an IQ Envoy not housed in an Enphase
Combiner, you can use screws to mount the adapter to the wall or a
board. Use one screw in each of the two recesses of the adapter. To
avoid damaging adapter housing, do not over tighten the screws
2
INSTALLATION
Preparation
You can install the Ensemble Communications Kit at any point during
the Ensemble system installation.
A ) Check that the IQ Envoy or IQ Combiner is de-energized.
1
DANGER! Risk of electric shock. Always de-energize the IQ Envoy or IQ Combiner before beginning the following procedure.
DANGER! Risk of electric shock. All sources to equipment being serviced must be disconnected external to the device. In
particular, the storage system may energize conductors, so storage circuits must ALWAYS be isolated via circuit breaker or
disconnect before working on any portion of the system
Plastic
deadfront
(the deadfront
on your com-
biner may be
transparent or
opaque).
Cable tie
Wireless
USB adapter
IQ Combiner 3C with
Ensemble Communications Kit installed
Cable tie