Bracket Spacing
Dimension
Description
Recommended Minimum
A
Enpower and Encharge horizontal bracket spacing
152 mm (6”)
B - Bottom aligned
Enpower wall mount bracket bottom to Encharge wall mount
bracket bottom
387 mm (15 1/4”)
B - Center aligned
Enpower wall mount bracket bottom to Encharge wall mount
bracket bottom
261 mm (10 5/16”)
B - Top aligned
Enpower wall mount bracket bottom to Encharge wall mount
bracket bottom
135 mm (5 5/16”)
C
Encharge wall horizontal bracket spacing
152 mm (6”)
Temperature Considerations
Unlike other battery chemistries, an Encharge storage system does not require ventilation for off-gassing and does
not require active cooling. Encharge storage system batteries perform best when not subjected to extreme hot or cold
temperatures and remain within the optimal temperature range of 0º C to 30º C (32º F to 86º F). Temperature may be
affected by location, exposure, and ventilation. Consider factors that may result in undesirable temperature swings
outside the optimal temperature range. For example, in enclosed unconditioned spaces such as garages or utility
closets, the temperature may be higher than the outdoor ambient.
Electrical Installation Requirements
For full installation instructions, always refer to the Enphase Installation Manuals, including the following documents:
Quick Install Guide Install the Enphase Encharge Storage System
Quick Install Guide Install the Enphase Enpower Smart Switch
Figure 11: Bracket Spacing