Specifications Sheet

Enphase
®
Engage Cable System // DATA
To learn more about Enphase Microinverter technology,
visit enphase.com
CABLE TYPES / ORDERING OPTIONS
Voltage Connector Spacing PV Module Orientation Model Number #Connectors* Weight**
240 VAC, 4 conductors 1.025 meter (40”) Portrait ET10-240-BULK 240 221 lbs
240 VAC, 4 conductors 1.7 meter (67”) Landscape ET17-240-BULK 240 333 lbs
208 VAC, 5 conductors 1.025 meter (40”) Portrait ET10-208-BULK 240 221 lbs
208 VAC, 5 conductors 1.7 meter (67”) Landscape ET17-208-BULK 240 333 lbs
*additional lengths available through Enphase authorized distributors. **weights are approximate
CABLE SPECIFICATIONS
Description Rating
Cable temperature rating 90°C (194°F) wet/dry
Cable insulator rating THWN-2
UV exposure rating UL 746 C, F1
Conductor size 12AWG
Compliance IEC 60529 IP67, CAN/CSA 22.2 No. 21, 182.3, UL 486A/B, 514C, 6703, and 9703
Cable rating TC-ER
Cable Diameter 1.25 cm (0.49”)
Minimum bend radius 12 cm (4.75”)
ENGAGE ACCESSORIES
Branch Terminator
One terminator needed per branch
circuit
ET-TERM-10 (sold in packs of 10)
Disconnect Tool
Plan to use at least one per
installation
ET-DISC-05 (sold in packs of 5)
Watertight Sealing Cap
One needed to cover each unused
connector on the cabling
ET-SEAL-10 (sold in packs of 10)
Cable Clip
Many needed to fasten cabling
to the racking or to secure looped
cabling
ET-CLIP-100 (sold in packs of 100)
Engage Coupler
Used for splicing two power cables
within an array
ET-SPLK-05 (sold in packs of 5)
© 2015 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. MKT-00071 Rev 1.0