Specifications
To learn more about Enphase offerings, visit enphase.com
© 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ
Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change.
2020-06-26
CONDUCTOR SPECIFICATIONS
Certication UL3003 (raw cable), UL 9703 (cable assemblies), DG cable
Flame test rating FT4
Compliance RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada and United States
Conductor type THHN/THWN-2 dry/wet
Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load-break
disconnect required by NEC 690.
Q CABLE TYPES / ORDERING OPTIONS
Connectorized Models
Size / Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box
Q-12-10-240
12 AWG / 277 VAC 1.3 m (4.2 ft) Portrait 240
Q-12-17-240
12 AWG / 277 VAC 2.0 m (6.5 ft) Landscape (60-cell) 240
Q-12-20-200
12 AWG / 277 VAC 2.3 m (7.5 ft) Landscape (72-cell) 200
ENPHASE Q CABLE ACCESSORIES
Name
Model Number Description
Raw Q Cable
Q-12-RAW-300 300 meters of 12 AWG cable with no connectors
Field-wireable connector (male)
Q-CONN-10M Make connections from any open connector
Field-wireable connector (female)
Q-CONN-10F Make connections from any Q Cable open connector
Cable Clip
Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling
Disconnect tool
Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount
Q Cable sealing caps (female)
Q-SEAL-10 One needed to cover each unused connector on the cabling
Terminator
Q-TERM-10 Terminator cap for unused cable ends
Enphase EN4 to MC4 adaptor¹
ECA-EN4-S22
Connect PV module using MC4 connectors to IQ micros with EN4 (TE PV4-S
SOLARLOK). 150mm/5.9” to MC4.
Enphase EN4 non-terminated adaptor¹
ECA-EN4-FW
For eld wiring of UL certied DC connectors. EN4 (TE PV4-S SOLARLOK) to
non-terminated cable. 150mm/5.9”
Enphase EN4 to MC4 adaptor (long)¹
ECA-EN4-S22-L
Longer adapter cable for EN4 (TE PV4-S SOLARLOK) to MC4. Use with split
cell modules or PV modules with short DC cable. 600mm/23.6”
Replacement DC Adaptor (MC4)
Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC)
Replacement DC Adaptor (UTX)
Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC)
1. Qualied per UL subject 9703.
Enphase
Q Cable Accessories
TERMINATOR
Terminator cap for unused cable
ends, sold in packs of ten
(Q-TERM-10)
SEALING CAPS
Sealing caps for unused aggregator
and cable connections
(Q-BA-CAP-10 and Q-SEAL-10)
DISCONNECT TOOL
Plan to use at least one per
installation, sold in packs of ten
(Q-DISC-10)
CABLE CLIP
Used to fasten cabling to the racking
or to secure looped cabling, sold in
packs of one hundred (Q-CLIP-100)