Specs
To learn more about Enphase offerings, visit enphase.com/au
© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc.
2018-01-23
INPUT DATA (DC) IQ7-60-2-INT IQ7PLUS-72-2-INT
Commonly used module pairings¹ 235 W - 350 W + 235 W - 440 W +
Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules
Maximum input DC voltage 48 V 60 V
Peak power tracking voltage 27 V - 37 V 27 V - 45 V
Operating range 16 V - 48 V 16 V - 60 V
Min/Max start voltage 22 V / 48 V 22 V / 60 V
Max DC short circuit current (module Isc) 15 A 15 A
Overvoltage class DC port II II
DC port backfeed under single fault 0 A 0 A
PVarrayconguration AC side protection requires max 20A per branch circuit
OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter
Peak output power 250 VA 295 VA
Maximum continuous output power 240 VA 290 VA
Nominal (L-N) voltage/range² 230 V / 184-276 V 230 V / 184-276 V
Maximum continuous output current 1.04 A 1.26 A
Nominal frequency 50 Hz 50 Hz
Extended frequency range 45 - 55 Hz 45 - 55 Hz
Maximum units per 20 A (L-N) branch circuit 16 (230 VAC) 13 (230 VAC)
Overvoltage class AC port III III
AC port backfeed current 0 A 0 A
Power factor setting 1.0 1.0
Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 lagging
EFFICIENCY @230 V @230 V
EN50530(EU)weightedefciency 96.5 % 96.5 %
MECHANICAL DATA
Ambient temperature range -40ºC to +65ºC
Relative humidity range 4% to 100% (condensing)
Connector type MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter)
Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket)
Weight 1.08 kg
Cooling Natural convection - No fans
Approved for wet locations Yes
Pollution degree PD3
Enclosure Class II double-insulated
Environmental category / UV exposure rating Outdoor - IP67
FEATURES
Communication Power Line Communication (PLC)
Monitoring Enlighten Manager and MyEnlighten monitoring options
Compatible with Enphase IQ Envoy
Compliance (pending) AS 4777.2, RCM, IEC/EN 61000-6-3,
IEC/EN 62019-1, IEC/EN 62109-2
1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility.
2. Nominal voltage range can be extended beyond nominal if required by the utility.
Enphase IQ 7 and IQ 7+ Microinverters