User's Manual
Table Of Contents
- 1 General description
- 2 Functional overview
- 2.1 Product description
- 2.2 Functional modes
- 2.3 Reporting interval
- 2.3.1 Energy considerations
- 2.3.2 Standard reporting interval
- 2.3.3 Illumination-controlled reporting interval
- 2.3.4 Temperature-controlled reporting interval
- 2.3.5 Humidity-controlled reporting interval
- 2.3.6 Acceleration-controlled reporting interval
- 2.3.7 Magnet contact sensor-controlled reporting interval
- 2.3.8 Arbitration between reporting intervals
- 3 Sensor functionality
- 4 Product interface
- 5 Radio communication
- 6 Security
- 7 Commissioning
- 8 NFC interface
- 9 NFC registers
- 9.1 NFC memory areas
- 9.2 Device identification NDEF
- 9.3 User information NDEF
- 9.4 NFC HEADER
- 9.5 CONFIGURATION
- 9.5.1 Using the NFC configuration functionality
- 9.5.2 CONFIGURATION area structure
- 9.5.3 NFC_PIN_CODE
- 9.5.4 PRODUCT_ID
- 9.5.5 USER_KEY
- 9.5.6 SECURITY_KEY_MODE
- 9.5.7 SECURITY_MODE
- 9.5.8 EEP
- 9.5.9 SIGNAL
- 9.5.10 LED_MODE
- 9.5.11 FUNCTIONAL_MODE
- 9.5.12 STANDARD_TX_INTERVAL
- 9.5.13 THRESHOLD_CFG1
- 9.5.14 THRESHOLD_CFG2
- 9.5.15 LIGHT_SENSOR_CFG
- 9.5.16 ACC_SENSOR_CFG
- 9.5.17 SOLAR_THRESHOLD
- 9.5.18 SOLAR_TX_INTERVAL
- 9.5.19 LIGHT_THRESHOLD
- 9.5.20 LIGHT_TX_INTERVAL
- 9.5.21 ACCELERATION_THRESHOLD
- 9.5.22 ACCELERATION_TX_INTERVAL
- 9.5.23 TEMPERATURE_THRESHOLD
- 9.5.24 TEMPERATURE_TX_INTERVAL
- 9.5.25 HUMIDITY_THRESHOLD
- 9.5.26 HUMIDITY_TX_INTERVAL
- 9.5.27 MAGNET_CONTACT_TX_INTERVAL
- 9.5.28 ILLUMINATION_TEST_RESULT
- 9.6 USER DATA
- 10 Mechanical interface
- 11 Installation recommendations
- 12 Regulatory notes
- 13 Product history
USER MANUAL
STM 550 / EMSI – ENOCEAN MULTISENSOR FOR IOT APPLICATIONS
© 2020 EnOcean | www.enocean.com F-710-017, V1.0 STM 550 / EMSI User Manual | v1.4 | November 2020 | Page 89/97
11.7 NFC configuration
STM 550 can be flexibly configured for a wide range of application scenarios using the NFC
configuration interface as described in chapters 8 and 9.
Before making any configuration changes, be sure to familiarize yourself with the device
functionality and determine the energy constraints based on the available ambient light as
discussed in chapter 2.3.1. Be especially careful not to configure higher update rates (low
reporting intervals) before ensuring that sufficient light is available.
Should you be unsure about the current NFC configuration, then execute a factory reset as
described in chapter 2.2.5 to reset all configuration registers to their default setting.
After completing the NFC configuration and ensuring that all functionality works as required,
it is recommended to lock the NFC configuration interface by changing the NFC PIN code from
its default value to a different (secret) value. Make sure the new PIN code is properly noted
down.