USER MANUAL V0.8 Transmitter Module PTM 33x / 33xC May 4, 2010 Observe precautions! Electrostatic sensitive devices! Patent protected: WO98/36395, DE 100 25 561, DE 101 50 128, WO 2004/051591, DE 103 01 678 A1, DE 10309334, WO 04/109236, WO 05/096482, WO 02/095707, US 6,747,573, US 7,019,241 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 info@enocean.com www.enocean.com Subject to modifications PTM 33x / 33xC User Manual V0.
USER MANUAL V0.8 PTM 33X / 33XC REVISION HISTORY The following major modifications and improvements have been made to the first version of this document: No Major Changes Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany www.enocean.com, info@enocean.com, phone ++49 (89) 6734 6890 © EnOcean GmbH All Rights Reserved Important! This information describes the type of component and shall not be considered as assured characteristics.
USER MANUAL V0.8 PTM 33X / 33XC TABLE OF CONTENT 1 1.1 1.2 1.3 1.4 1.5 2 FUNCTIONAL DESCRIPTION .......................................................................... 6 2.1 Block diagram............................................................................................. 6 2.2 Pin out....................................................................................................... 7 2.3 Pin Description and operational characteristics................................................. 7 2.
USER MANUAL V0.8 PTM 33X / 33XC 1 GENERAL DESCRIPTION 1.1 Basic Functionality The radio transmitter module PTM 330 from EnOcean enables the implementation of wireless sensors and switches without batteries. Key applications are handheld remote controls or industrial switches. Functional Principle When an energy pulse is supplied (e.g.
USER MANUAL V0.8 PTM 33X / 33XC 1.3 Physical Dimensions PCB dimensions © 2009 EnOcean | www.enocean.com 26.2 x 21.15 x 3.5 mm PTM 33x / 33xC User Manual V0.
USER MANUAL V0.8 PTM 33X / 33XC 1.4 Environmental Conditions Operating temperature -25 °C … +85 °C Storage temperature -40 °C … +85 °C Storage temperature in Tape&Reel -20 °C … +50 °C Humidity 1.5 0% … 93% r.h., non-condensing Ordering Information Type Ordering Code PTM 330 S3001-A330 PTM 332 S3001-A332 PTM 330C S3031-A330 PTM 332C S3031-A332 Frequency 868.3 MHz 868.3 MHz 315.0 MHz 315.0 MHz 2 FUNCTIONAL DESCRIPTION 2.
USER MANUAL V0.8 PTM 33X / 33XC 2.2 Pin out GND 1 CFG 16 AC1 2 15 AC2 B0 3 14 GND GND 4 13 V+ B1 5 12 GND A0 6 11 RF_50 GND 7 10 GND A1 8 AC1 AC2 T1 T4 T3 T8 T6 AC2 T5 T7 T9 AC1 T2 9 RF_WHIP On back side of PCB 2.
USER MANUAL V0.8 PTM 33X / 33XC 2.4 Configuration Interface Via the programming interface the telegram content can be modified.
USER MANUAL V0.8 PTM 33X / 33XC 2.5 Absolute maximum ratings (non operating) Symbol AC1 AC2 GND A0 A1 B0 B1 2.6 Parameter Supply voltage Ground connection Min 0 0 0 Max 6.4 0 0 Units V V V Voltage digital input pins Maximum Ratings (operating) Symbol AC1 AC2 GND A0 A1 B0 B1 Parameter Supply voltage Ground connection Min 0 0 0 Max 6.0 0 0 Units V V V Voltage digital input pins © 2009 EnOcean | www.enocean.com PTM 33x / 33xC User Manual V0.
USER MANUAL V0.8 PTM 33X / 33XC 2.7 Radio telegram 2.7.1 Normal operation In default configuration PTM 33x transmits the same telegrams as a PTM 200 radio switch: Telegram type RPS: There are two message types depending on how many buttons (A0, A1, B0, B1) have been pressed (connected to GND) o N-message: Only one or two buttons have been pressed. o U-message: No pushbutton was pressed when activating the energy generator, or more than two pushbuttons have been pressed.
USER MANUAL V0.8 PTM 33X / 33XC U-message: DATA_BYTE3: 7 0 BUTTONS BUTTONS PR Reserved (3 bit) Number of simultaneously pressed buttons, as following: 0 = 0 Button 1 = not possible 2 = not possible 3 = 3 or 4 buttons 4 = not possible 5 = not possible 6 = not possible 7 = not possible PO Reserved (1 bit) (4 bit) Polarity, see table below STATUS: 7 Reserved 0 T21 Reserved T21 NU RP_COUNTER NU (2 (1 (1 (4 RP_COUNTER bit) bit) bit) bit) For future use 1 NU=0 Æ U-message.
USER MANUAL V0.8 PTM 33X / 33XC 3 APPLICATIONS INFORMATION 3.1 How to connect an energy harvester PTM 330 can be connected to ECO 200 without soldering. ECO 200 provides contact springs which can directly be connected to contact pads of PTM 330. The contact pads on the bottom of the PCB are shown below (left). A second orientation where PTM 330 is rotated 180° with respect to ECO 200 is also possible as shown with dashed lines. 3.2 How to generate an equivalent energy pulse © 2009 EnOcean | www.
USER MANUAL V0.8 PTM 33X / 33XC 3.3 Antenna 315 MHz Option 1: 150 mm wire, connect to RF_WHIP Option 2: A 50Ω antenna can be connected to RF_50. In this case the limited modular FCC/IC approval is not valid! An FCC/IC approval is then needed for the end device! 868 MHz Option 1: 87 mm wire, connect to RF_WHIP Option 2: A 50 Ω antenna can be connected to RF_50 Specification of the whip antenna; L=150 mm @ 315 MHz, L=87 mm @ 868 MHz © 2009 EnOcean | www.enocean.com PTM 33x / 33xC User Manual V0.
USER MANUAL V0.8 PTM 33X / 33XC 3.4 Layout recommendations Proposal for foot print on host PCB Keep out area on host PCB. No copper surface area allowed! © 2009 EnOcean | www.enocean.com PTM 33x / 33xC User Manual V0.
USER MANUAL V0.8 PTM 33X / 33XC 3.5 Soldering information PTM 332/332C PTM 332 has to be soldered according to IPC/JEDEC J-STD-020C standard. PTM 332 shall be handled according to Moisture Sensitivity Level MSL4 which means a floor time of 72 h. PTM 332 may be soldered only once, since one time is already consumed at production of the module itself. Once the dry pack bag is opened, the desired quantity of units should be removed and the bag resealed within two hours.
USER MANUAL V0.8 PTM 33X / 33XC 3.6 Transmission range The main factors that influence the system transmission range are type and location of the antennas of the receiver and the transmitter, type of terrain and degree of obstruction of the link path, sources of interference affecting the receiver, and “Dead” spots caused by signal reflections from nearby conductive objects.
USER MANUAL V0.8 PTM 33X / 33XC 4 AGENCY CERTIFICATIONS (in preparation) The modules have been tested to fulfil the approval requirements for CE (PTM 33x) and FCC/IC (PTM 33xC) based on the built-in firmware. 4.1 CE approval The modules bear the EC conformity marking CE and conforms to the R&TTE EU-directive on radio equipment. The assembly conforms to the European and national requirements of electromagnetic compatibility.
USER MANUAL V0.8 PTM 33X / 33XC 4.2 FCC (United States) Certification PTM330C and PTM332C LIMITED MODULAR APPROVAL This is an RF module approved for Limited Modular use operating as an intentional transmitting device with respect to 47 CFR 15.231(a-c) and is limited to OEM installation. The module is optimized to operate using small amounts of energy, and may be powered by a battery.
USER MANUAL V0.8 PTM 33X / 33XC The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product. Attaching a label to a removable portion of the final product, such as a battery cover, is not permitted. The label must include the following text: Contains FCC ID: SZV-PTM33XC The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (i.
USER MANUAL V0.8 PTM 33X / 33XC 4.3 IC (Industry Canada) Certification In order to use EnOcean’s IC number, the OEM must ensure that the following conditions are met: Labeling requirements for Industry Canada are similar to those required by the FCC. The Original Equipment Manufacturer (OEM) must ensure that IC labeling requirements are met.