USER MANUAL V0.6 Transmitter Module PTM 335 / 335C October 6, 2011 Observe precautions! Electrostatic sensitive devices! Patent protected: WO98/36395, DE 100 25 561, DE 101 50 128, WO 2004/051591, DE 103 01 678 A1, DE 10309334, WO 04/109236, WO 05/096482, WO 02/095707, US 6,747,573, US 7,019,241 EnOcean GmbH Kolpingring 18a 82041 Oberhaching Germany Phone +49.89.67 34 689-0 Fax +49.89.67 34 689-50 info@enocean.com www.enocean.com Subject to modifications PTM 335 / 335C User Manual V0.
USER MANUAL V0.6 PTM 335 / 335C REVISION HISTORY The following major modifications and improvements have been made to the first version of this document: No 0.5 0.6 0.7 Major Changes Initial version Updated version, delivered with B-samples Output power data 868 MHz updated Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany www.enocean.com, info@enocean.
USER MANUAL V0.6 PTM 335 / 335C TABLE OF CONTENT 1 1.1 1.2 1.3 1.4 1.5 GENERAL DESCRIPTION ................................................................................. 4 Basic Functionality ......................................................................................... 4 Technical Data .............................................................................................. 4 Physical Dimensions.......................................................................................
USER MANUAL V0.6 PTM 335 / 335C 1 GENERAL DESCRIPTION 1.1 Basic Functionality The radio transmitter module PTM 335 from EnOcean enables the implementation of wireless sensors door sensors without batteries. Functional Principle When an energy pulse is supplied by ECO 200 an RF telegram is transmitted including a unique 32-bit module ID, and information if an open or close event has happened. This information is derived from the polarity of the energy pulse.
USER MANUAL V0.6 PTM 335 / 335C © 2011 EnOcean | www.enocean.com PTM 335 / 335C User Manual 0.
USER MANUAL V0.6 PTM 335 / 335C 1.4 Environmental Conditions Operating temperature -25 °C … +65 °C Storage temperature -40 °C … +85 °C Humidity 1.5 0% … 93% r.h., non-condensing Ordering Information Type PTM 335 PTM 335C Ordering Code S3001-A335 S3031-A335 2 FUNCTIONAL DESCRIPTION 2.1 Block diagram Frequency 868.3 MHz 315.0 MHz At power-up by an energy pulse at AC1, AC2 a DC voltage is provided to the internal micro controller.
USER MANUAL V0.6 PTM 335 / 335C 2.3 Absolute maximum ratings (non operating) Symbol Parameter AC1 Supply voltage AC2 2.4 Max 17 Units V Min 0 Max 15 Units V Maximum Ratings (operating) Symbol Parameter AC1 Supply voltage AC2 2.5 Min 0 Radio telegram PTM 335 transmits a radio telegram according to EEP F6-10-00. Status “open” is represented by 0xC0 (ECO 200 tension spring “up” = towards PCB) Status “closed” is represented by 0xF0 (ECO 200 tension spring “down” = away from PCB) http://www.
USER MANUAL V0.6 PTM 335 / 335C 3 APPLICATIONS INFORMATION 3.1 Transmission range The main factors that influence the system transmission range are type and location of the antennas of the receiver and the transmitter, type of terrain and degree of obstruction of the link path, sources of interference affecting the receiver, and “dead” spots caused by signal reflections from nearby conductive objects.
USER MANUAL V0.6 PTM 335 / 335C 4 AGENCY CERTIFICATIONS (after release for series production) The modules have been tested to fulfil the approval requirements for CE (PTM 335) and FCC/IC (PTM 335C) based on the built-in firmware. 4.1 CE approval The module bears the EC conformity marking CE and conforms to the R&TTE EU-directive on radio equipment. The assembly conforms to the European and national requirements of electromagnetic compatibility.
USER MANUAL V0.6 PTM 335 / 335C 4.2 FCC (United States) Certification PTM 335C LIMITED MODULAR APPROVAL This is an RF module approved for Limited Modular use operating as an intentional transmitting device with respect to 47 CFR 15.231(a-c) and is limited to OEM installation. The module is optimized to operate using small amounts of energy, and may be powered by a battery.
USER MANUAL V0.6 PTM 335 / 335C (ii.) this device must accept any interference received, including interference that may cause undesired operation. When the device is so small or for such use that it is not practicable to place the statement above on it, the information required by this paragraph shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed.