User's Manual

USER MANUAL V1.2
PTM 33X / PTM 33XC / PTM 330U
3.4 Configuration Interface
Via the programming interface the telegram content can be modified.
The interface is shown in the figure below:
EnOcean provides EOPx (EnOcean Programmer, a command line program) and Dolphin
Studio (Windows application for chip configuration, programming, and testing) and the
USB/SPI programmer device as part of the EDK 300 developer’s kit. In order to contact
PTM 330 programming and testing points a needle bed adapter is needed.
Pad
Symbol
Function
Characteristics
T1
VDD
Supply voltage
Interface to programmer; Max. 3.3 V
T2
GND
Ground connection
Interface to programmer
T3
SCSEDIO0
SPI chip select
Interface to programmer
T4
SCLKDIO1
SPI serial clock
Interface to programmer
T5
WSDADIO2
SPI input
Interface to programmer
T6
RSDADIO3
SPI output
Interface to programmer
T7
RESET
Reset
Interface to programmer, internal pull
down
T8
ADIO7
Sync output
T9
PROG_EN
Enable programming mode
Interface to programmer
HIGH: programming mode active
LOW: operating mode
Internal pull-down
3.5 Absolute maximum ratings (non operating)
Symbol
Parameter
Min
Max
Units
AC1
AC2
Supply voltage
0
6.4
V
GND
Ground connection
0
0
V
A0
A1
B0
B1
Voltage digital input pins
0
0
V
USB <=
> SPI
interface
SPI
USB
Dolphin Studio, or EOPx
Reset
PROG_EN
ADIO7
SCSEDIO0
SCLKDIO1
WSDADIO2
RSDADIO3
PTM
PTM 330