User's Manual
USER MANUAL
PTM 215ZE – 2.4 GHz IEEE 802.15.4 Pushbutton Transmitter Module
© 2022 EnOcean | www.enocean.com F-710-017, V1.0 PTM 215ZE User Manual | v1.0 | March 2022 | Page 28/43
6.3.7 Password authentication (PWD_AUTH) command
The protected memory area can be accessed only after successful password verification
via the PWD_AUTH command.
The PWD_AUTH command takes the password as parameter and, if successful, returns the
password authentication acknowledge, PACK.
Figure 16 below shows the password authentication sequence.
Figure 16 – Password authentication sequence
After successful authentication, the password can be changed by writing the new password
to memory page 0xE5.
Note that a read access to page 0xE5 always return 0x00000000, i.e. it is not possible to read
out the current PIN code.