3.3.1 Button Contact Encoding
Table 2 below shows the supported single and dual button contact actions of PTM 215ZE
together with the encoding used for the transmission.
In this table, the meaning of “0” and “1” is the following for press and release events:
0
Button is not pressed upon push
Button was not pressed before release
1
Button is pressed upon push
Button was pressed before release
A0
A1
B0 B1 Energy Bar Command
0 0 0 0 Press 0x10
0 0 0 0 Release 0x11
0 0 0 1 Press 0x12
0 0 0 1 Release 0x13
0 0 1 0 Press 0x14
0 0 1 0 Release 0x15
0 1 0 0 Press 0x18
0 1 0 0 Release 0x19
1 0 0 0 Press 0x22
1 0 0 0 Release 0x23
0 0 1 1 Press 0x16
0 0 1 1 Release 0x17
0 1 0 1 Press 0x1A
0 1 0 1 Release 0x1B
0 1 1 0 Press 0x1C
0 1 1 0 Release 0x1D
1 0 0 1 Press 0x1E
1 0 0 1 Release 0x1F
1 0 1 0 Press 0x62
1 0 1 0 Release 0x63
1 1 0 0 Press 0x64
1 1 0 0 Release 0x65