Installation Instructions
Table Of Contents
Page 2 Page 3 Page 4
Note: For any reason, if you need to remove the two
wires, push down on the tabs of the sensor with a
pointed device, and remove the wires while
continuing to hold the tab down.
To Enlighted
sensor
To
lamps
From Mains Power
The two-wire Fixture Mount sensor is designed to mount
in a ½ inch trade size knockout. All parts of the sensor
are inside the lighting fixture except for the outer ring.
This sensor is for use with LED drivers and devices
supporting a compatible two-wire interface.
Step 1: Switch off the circuit breaker supplying power to
the light fixture.
Step 2: Determine the location for the sensor in the fixture.
Step 3: Remove an existing ½ inch knockout or cut a
hole in the fixture.
Step 4: Measure the distance between the sensor’s
installation location and the LED driver.
Step 5: Cut two lengths of 18 AWG solid wire that are
at least this measured length plus one inch. Strip each
end of the two wires leaving 3/8 inch of exposed wire.
Step 6: Insert one end of the pair of wires into the LED
driver’s connections wire holes.
Step 7: Remove the outer ring from the sensor by
unthreading it. Keep the spring washer and inner ring on
the sensor.
Step 9: Close the light fixture and restore power to the
fixture. Wait for the green LED to start blinking. See LED
descriptions on page 5.
Step 8: Insert the sensor assembly into the knockout
that was cut out of the light fixture. Thread the outer
ring back on the sensor. Tighten firmly but do no over
tighten. If you have a thick fixture, do not use the inner
ring.
Note: Make sure that the sensor antenna passes
through the knockout and does not get caught in the
rings or assembly.
Sensor Antenna
Installation
Caution
Installation and maintenance must be performed by a
qualified electrician in accordance with local, state, and
national electrical codes (NEC) and requirements.