User manual

Code: ENIGMA III User Manual
Edition: 1 Revision: 4
Date: 19/12/2008
Page: 86/97
8.7 settxdtrigger
Enable/disable transmitter trigger
Parameter: 0 – Disable trigger, 1- Enable trigger
8.8 geterrorconditions
Get the internal errors from the PCI-Receiver card. The command resets all errors.
Parameter: None
Returns: Space separated list of error codes
1 - Error: PCI external FIFO full
2 - Error: Fiber downlink laser detection
3 - Error: Fiber downlink synchronization loss
4 - Error: PCI internal FIFO full
5 - Error: Downlink data header word 0
6 - Error: Downlink data header word 15
7 - Error: PCI pass through
8 - Error: PCI pass through unknown command
9 - Error: Filter coefficients command
10 - Error: PCI External FIFO Full
11 - Error: Uplink
128 - Warning: PCI external FIFO almost full
129 - Warning: Unambiguous range number of bins
130 - Warning: Filter coefficients command
131 - Warning: PRF command";
8.9 build
Returns the 'buildstring' of the ENIGMA host firmware.
Example: build errormsg=null version=1.3.16 SIAMCC_LINUX26
Host software version is 1.3.16 and was compiled for kernel 2.6.x
8.10 load
Load parameter from previously stored configuration file. The configuration files are located in
/opt/enigma3. The filename is controlagent_X.is (with X corresponding to SDPType)
GAMIC Proprietary