User manual
Code: ENIGMA III User Manual
Edition: 1 Revision: 4
Date: 19/12/2008
Page: 70/97
7.7 AFCSettings
Parameters: staloID staloMinTuneRFFreq staloMinTuneUnit staloMaxTuneRFFreq staloMaxTuneUnit
afcCoarseFreqStep afcFineFreqStep afcTuneBandwidth afcBurstIFFreq afcFreqThresh
afcBurstPowerThresh afcLoopSettingTime afcStaloNominalFreq flags
staloID - uint
staloMinTuneRFFreq - float in MHz
staloMinTuneUnit - float in V
staloMaxTuneRFFreq - float in MHz
staloMaxTuneUnit - float in V
afcCoarseFreqStep - float in kHz
afcFineFreqStep - float in kHz
afcTuneBandwidth - float in MHz
afcBurstIFFreq - float in MHz
afcFreqThresh - float in kHz
afcBurstPowerThresh - floa in dBt
afcLoopSettingTime - float in ms
afcStaloNominalFreq - float in MHz
flags - uint, bits with following masks control the settings
0x0001 - Negative AFC Tuning Slope
0x0002 - Invert IQ
0x0100 - AFC
0x0200 - MFC
0x0400 - MFC Hold
0x0800 - AFC Search
0x1000 - Set Mode Only
7.8 DualPolMode
If true, dual polarization mode is used, otherwise single polarization mode. Ray format depends on the
parameter.
Type: boolean
Default: false
7.9 Dual polarization specific parameter
When used in dual polarization mode the ENIGMA signal processor will use the following cammands in
addition to the standard commands.
GAMIC Proprietary