It is normalized to the Nyquist interval [-1;1].
Phase unfolding is performed in dual-PRF mode using PRFs ratio.Supported values are 2:3, 3:4 and 4:5.
7.6 Acquisition parameter
Acquired data are available over the separate TCP connection. SDP listens on the port 5556 for incoming
connection. Only one is established at the time.
Some parameters configure the transmission of the acquired data.
7.6.1 RaySize
Expected by client ray size in bytes. This is for the FrogRadar compatibility. If expected raysize equals to
0, it is not taken into account. SDP shrinks or grows the amount of bytes in the ray to this value.
Additional bins filled with 'thresholded' value.
Type: integer
Default: 0
Related parameter: LongRaySize
7.6.2 LongRaySize
If this parameter is set to true, the raysize word in the ray header will be 32bit instead of 16bit. It is
recommended to set this parameer to true if you want to work with 16bit moments and large amounts of
bins.
Type: boolean
Default: false
7.6.3 SyncModeParam
Argument format: <mode> <angle_step> <pulses>
<mode> - Syncing modes may be:
0 - Timesampling
1 - Azimuth Dynamic Angle Syncing
2 - Elevation Dynamic Angle Syncing
<angle_step> angle step in dynamic angle syncing mode. It is in decimal degrees, floating point
<pulses> is the number of pulses for averaging in timesampling mode.
GAMIC Proprietary