Byte 4
D7 D6 D5 D4 D3 D2 D1 D0
0 EL8 EL7 EL6 EL5 EL4 EL3 EL2
Byte 5
D7 D6 D5 D4 D3 D2 D1 D0
0 CSUM6 CSUM5 CSUM4 CSUM3 CSUM2 CSUM1 CSUM0
6.5 Extended Dynamic Range
In single polarization mode the ENIGMA IFD has the ability to stack two converters (Build 100 or
above). The low channel is connected to the horizontal input and the high channel is connected to the
vertical input.
To enable/disable the channel stacking use the ExtendedDynamicRange parameter.
6.5.1 ExtendedDynamicRange
Type: boolean
Default: false
There are a few configuration parameters related to this, Basically three things need to be adjusted.
The level where switching between the two ad-converters is performed. The corresponding parameter is
called PowerThreshold.
6.5.2 PowerThreshold
Set the level (in %) for the lower channel for converter switchover
Type: float