User manual

Code: ENIGMA III User Manual
Edition: 1 Revision: 4
Date: 19/12/2008
Page: 46/97
Remark: Only the baud rate is configurable. The other serial parameter are fixed. 1 stop bit. 1 start
bit and no parity will be used.
6.4.2 IFDTagBaudRate
Specify the baudrate for the RS422 TAG input at the ENIGMA IFD+. The ENIGMA IFD III+ provides
an additional input for the serial angle tags The baudrate can be specified directly in baud
(1200...4000000) and can also be a “non-standard” value like 500000 (500kbits/s).
Type: integer
Default: 9600
Unit: baud
Remark: Only the baud rate is configurable. The other serial parameter are fixed. 1 stop bit. 1 start
bit and no parity will be used.
6.4.3 TagConfiguration
With ENIGMA IFD III+ the input for the angle TAGS can be freely defined. The ENIGMA IFD III only
provides the option for angle TAGS at the host.
Type: integer
Default: 0
Possible value:
0: Parallel tags at PCI Receiver card
1: Serial tags at PCI Receiver card
2: Serial tags at IFD (IFD+ only)
3: Azimuth at PCI Receiver card, Elevation at IFD (IFD+ only)
4: Elevation at PCI Receiver card, Azimuth at IFD (IFD+ only)
6.4.4 SerialTagFormat
Type: integer
Default: 0
Two serial TAG formats are supported:
Data packet Format 0
7 Bytes are transmitted. First Byte is a frame syncing Byte ($80).
Byte 1 – Byte 5 contain 16 bit azimuth and elevation information:
AZ15 (MSB) - AZ0 (LSB)
EL15 (MSB) - EL0 (LSB)
GAMIC Proprietary