User manual

Code: ENIGMA III User Manual
Edition: 1 Revision: 4
Date: 19/12/2008
Page: 38/97
6 Parametrization
There are many commands and parameters supported by the SDP.
The list of commands and parameters with short descriptions can be obtained through the 'help'
command:
help
SDP responds with a text similar to the shown below::
Format: help [<command_name> | <param_name>]
Where command_name is:
get: get parameter
getadcdiff: get phase and power difference for hi/lo channels
getafcstatus: Get AFC status
getasciistatus: Request status from IFD and PCI receiver
getburst: get burst parameters
getconverter: converter status
geterrorconditions: Get error conditions
getifsampling: Get IF Sampling Parameters
getpower: power status
gettemperature: temperature
getversion: get hardware version numbers
load: load parameters
noisesample: Noise sampling
sampleburst: get burst samples
save: testsave parameters
set: set parameter
setafcmode: Set AFC Mode
setpulsewidth: Set Pulse Width Index
settxdtrigger: Set TxD trigger
startacq: start acquisition
stopacq: stop acquisition
param_name is:
AFCSettings: AFC settings
AcfMode: ACF mode
AzimuthAbsoluteOffset: calibratiobn offset for antenna alignment
AzimuthSynchroOffset: calibratiobn offset for encoder/synchro diference
BurstTiming0: burst sample timing
BurstTiming1: burst sample timing
BurstTiming2: burst sample timing
BurstTiming3: burst sample timing
CCORThreshold: CCOR threshold
ClutterFilter: Clutter filter number
ClutterMicroSuppression: Set clutter micro suppression
ClutterMicroSuppressionThreshold: Clutter micro suppression threshold
GAMIC Proprietary