Specifications
Power-up Modes: Trouble-shooting Tools
101 VisiLogic: Getting Started
Mode
F
eatures
P
ossible Actions
E
X-RC1
V120/130
V230/260
V
280
V350/290/530/
570/V1040
(touchscreen)
Bootstrap
The controller's LCD is on.
PC-PLC communications
are enabled, but PC must
b t d t COM 1.
-Via Vision Communication
PC Settings, you can:
Check which OS is
currently installed in the
controller.
Move all DIP switches to 1
<I> +
<ESC>
<I> +
<Right Arrow>
<I> +
<Right Arrow>
Turn the PLC off.
Enter Bootstrap mode by
touching the screen and
maintaining contact while
turning the power on.
Bootstrap version V2.00
and up
- If no action is taken, the
PLC enters Run mode after
several seconds.
Stop (O/S)
As in Bootstrap, but Info
mode can be entered.
As above, but all Info
mode actions are
supported.
Exit Stop Mode by
entering Information
Move all DIP switches to
<I>
<I>
<I>
Turn the PLC off.
Enter Bootstrap mode
by touching the screen
and maintaining contact
while turning the power
on.
Enter Stop mode by
pressing the screen
once.
Note • Visions embedded
Bootstrap,
default LCD contrast
Contrast range is 0-
100, this option
automatically sets
Contrast to 50.
<I> +
<ESC> +
<+/->
<I> +
<Right Arrow> +
<+/
>
Stop (O/S,
default LCD contrast
Contrast range is 0-100, this
option sets Contrast to 50.
<I> +
<+/->
<I> +
<+/->