REPLACINGCOMPONENTS
ConvectionBlower
1. Beforebeginninganycomponentreplacement,becertaintheunitisunpluggedandthoroughly
cooleddown.
2. Removetherearpanel(usinga
5
/
16
”wrench)andlocatetheconvectionblower.
3. Detachtheconvectionblowerfromthewiringharnessbeforegoinganyfurther.
4. Loosenandremovethetwoscrewswhichholdtheblowertothestove;removetheblower
fromthestove.
5. Installationofthenewblowerisperformedinreverseofremoval;remembertoreconnectthe
newblowertothewiringharness.(Wheninstallingthenewblower,placetheflangeofthe
bloweronthebottombracketoftheblowerhousing.)
CombustionBlower
1. Beforebeginninganycomponentreplacement,becertaintheunitisunpluggedandthoroughly
cooleddown.
2. Removetheleftsidepanelandlocatethecombustionblower(seep.43forpanelinstructions).
3. Disconnecttheventingsystemfromtheexhaustblower,anddisconnecttheexhaustblower
fromthestove
wiringharness.Toremovetheventingpipe,removaloftherearpanel(usinga
5
/
16
”wrench)maybenecessary.
4.
Removeallfivescrewswhichholdtheexhaustblowertotheexhaustblowertube.Oncethe
screwshavebeenremoved,theblowercanbeliftedupandoutofthestove.
5. Reinstallationistheexactoppositeofthestepsabove;however,becertaintocheckthe
conditionoftheexhaustblowergasketandreplaceifnecessary.