Specifications

DescriptionProperty
If set to yes, Switch ensures that all files receive a filename extension
corresponding to the Mac file type and file creator codes (if these are present);
for more information see the separate topic on Mac file types on page 194.
Add filename
extension
Processing
These preferences configure some aspects of how Switch processes jobs.
DescriptionProperty
The number of FTP and email file transfers (counting both send and
receive) allowed to occur in parallel
Concurrent file
transfers
The number of file transfers to the same FTP site allowed to occur in
parallel (counting both send and receive)
Concurrent transfers to
the same site
Automatic means that there is no limit other than the overall maximum
number of concurrent file transfers as determined by the previous
preference
The number of third-party applications and compress/uncompress
processes allowed to run in parallel
Concurrent external
processes
The number of slots available for scripts and tools working in concurrent
mode. By default, this property is set to "1", this will cause a serialized
Default number of slots
for concurrent
elements execution mode. Change the number of slots to more than 1 to execute
in concurrent mode. Setting this property to "0" means all available
slots will be used.
In PowerSwitch, this default value from the preferences can be overruled
by
1.
Setting the flow property Allow advanced performance tuning to
yes
2.
Changing the element property "number of slots" from default to
any other value.
Performance tuning properties and preferences need to be set cautiously
because however they are made to speed up processing, unwary use
may slow down performance.
The frequency with which input folders (i.e. the folders without
incoming connections) and submit hierarchies are scanned for newly
arrived jobs
Scan input folders
every (seconds)
The frequency with which intermediate folders (i.e. the folders with
incoming connections) are scanned for newly arrived jobs
Scan intermediate
folders every (seconds)
Note that jobs placed in an intermediate folder by Switch are detected
and processed immediately and without waiting for the next scan
187
Enfocus Switch 10