Specifications
34
D O I T Y O U R S E L F
ENGINE - OIL CHANGE
Secondary
Drain Plug
Primary
Drain Cap
Primary
Drain Bolt
(Refer Periodical Maintenance Chart for frequency)
Place motorcycle on its center stand on a firm flat
surface.
Start engine and warm up for 2 minutes.
Keep a clean tray below the engine
Remove primary drain cap, to drain oil & clean
suction filter, magnet.
Then remove secondary drain plug to drain oil &
clean the magnet.
Finally remove primary drain bolt to drain the
complete oil.
Remove the oil filter element on the Crankcase
Cover RH.
Allow the oil to drain by tilting the motorcycle to
both sides.
Wash the drain pl ug and the suction fil te r
thoroughly and refit on the crankcase after all the
oil is drained out.
Soak a new oil filter element in the oil and refit on
the Crankcase Cover RH.
Assembly 3 bolts and tighten them. Ensure ‘O’
Ring and gaskets are taken seat properly.
NOTE :
Replace oil f il te r e le ment whenever oil is being
replaced.
CAUTION :
Filling up oil over “MAX” mark may cause smoke and
/ or loss of power. Do NOT allow oil level to fall below
“MIN” mark. Doing so may result in engine internal
damage or malfuncton.
Fill recomme nded oil to
engine till the oil level is
upto “MAX” level mark in
the oil window in Crank-
case Cover RH.
Max
Min