7 CLEARANCESTOHEATSENSITIVEMATERIALS
Itisofoutmostimportancethattheclearancestoheatsensitivematerialsbecarefullymaintained
uponinstallationofthewoodfireyouhaveselected.Refertothetablesbelow.
No part of the wood fire or flue may be located closer to combustibles than the minimum
clearancefiguresgiven.
7.1 LOCATIONOFTHECERTIFICATIONLABEL
Sincetheinformationgivenonthecertificationlabelaffixedtotheappliancealwaysoverridesthe
informationpublished,inanyothermedia(owner’smanual,catalogues,flyers,magazinesand/or
web sites) it is important to refer to it in order to have a safe and compliant installation. In
addition,youwillfindinformationaboutyourwoodfire(model,serialnumber,etc.).Youcanfind
thecertificationlabelonthebackofthewoodfire.
7.2 CLEARANCESTOWALLSANDCEILING
WHERETHEFLUEPASSESTHROUGHAWALL,CEILING,FLOORORROOFS,VENTILATEDDOUBLE
FLUEWOOD FIRE CASINGS MUST BE USED AROUND THE FLUE, ALONG WITH CEILING PLATES
ASSPECIFIEDINAS/NZS2918:2001.THECASINGSHALLPASSTHROUGHTHEENTIRETHICKNESS
OFWALL,CEILINGORWALL.
See figure Clearances to heatsensitive materialsand floor protection to match each letter to a
clearance.
CLEARANCES
A 275mm
B 775mm
C 325mm
F 1m
Topofappliancetoceilingheightmustbeatleast1,200mminallcases.
Theclearancebetweentheflueandawallarevalidonly forverticalwallsandfor vertical
flue.