Specifications
28 Solution3.4InstallationandOperationManual
PARTB–INSTALLATION
Itisveryimportanttopositionthewoodfireascloseaspossibletothefluesystem,andinanarea
thatwillfavourthemostefficientheatdistributionpossiblethroughoutthehouse.Thewoodfire
must therefore be installedinthe room wherethe most timeisspent, and in themost spacious
roompossible.Recallthatwoodfiresproduceradiatingheat,the heatwefeelwhenweareclose
toawoodfi re.Awoodfirealsofunctionsbyconvectionthatisthroughthedisplacementofhot
airacceleratedupwardsanditsreplacementwithcoolerair.Ifnecessary,thehotairdistribution
fromthewoodfiremaybefacilitatedbytheinstallationofafan.
6 SAFETYINFORMATION
6.1 SUMMARYOFINSTALLATIONCAUTIONSANDWARNINGS
• THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE
ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER’S
MANUAL,CATALOGUES,FLYERS,MAGAZINESAND/ORWEBSITES).
• MIXING OF APPLIANCE OR FLUE‐SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR
MODIFYING COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS. WHERE ANY SUCH
CHANGESAREPLANNED,THEMANUFACTURERSHOULDBECONTACTEDINADVANCE.
• A WOOD FIRE MUST NEVER BE INSTALLED IN A HALLWAY OR NEAR A STAIRCASE, SINCE IT
MAYBLOCKTHEWAYINCASEOFFIREORFALLTORESPECTREQUIREDCLEARANCES.
• CONNECTTHISWOODFIREONLYTOTRIPLESKINFLUEKITASPERAS/NZS2918,APPENDIXB,
ORANYFLUESYSTEMTESTEDTOANDPASTTHEREQUIREMENTSOFAS/NZS2918,APPENDIX
F, FOR USE WITH SOLID FUEL OR TO A LINED MASONRY FLUE SYSTEM CONFORMING TO
NATIONALANDLOCALBUILDINGCODES.
• USESMOKEDETECTORSINTHEROOMWHEREYOURWOODFIREISINSTALLED.
• IFREQUIRED,ASUPPLYOFCOMBUSTIONAIRSHALLBEPROVIDEDTOTHEROOMORSPACE.
• KEEPFURNITUREANDDRAPESWELLAWAYFROMTHEWOODFIRE.
• DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK
UNLESSSPECIFICALLYAPPROVEDFORSUCHINSTALLATION.
• DONOTCONNECTTHISUNITTOAFLUEORFLUESYSTEMSERVINGANOTHERAPPLIANCE.