70 Solution 2.5-ZC Fireplace Installation and Operation Manual   
Appendix 1: Hot Air Ducting Installation 
Different hot air ducting systems can be installed with the SOLUTION 2.5-ZC: 
Gravity kit 
Forced air kit 
Gravity Kit (AC01309) 
The kit includes: 
 2 x hot air outlets (grilles and frames); 
 2 x 90
o
 elbows with brackets; 
 1 block-off plate. 
The gravity kit allows you to block the upper fireplace louver. To do so, follow the steps 
below: 
a)  Remove the upper louver from the fireplace; 
b)  Install the deflector as shown on figure on the left; 
c)  Put the upper louver back into place. 
The safety rules for hot air ducting gravity kit installations are the following: 
  Minimum height*    68" (1.7 m) 
  Maximum length    10' (3m) (see figure 22) 
*The minimum height of the hot air ducting must be measured from the floor to the top of 
the hot air grilles. 