Specifications
Solution 2.5-ZC Fireplace Installation and Operation Manual  41 
6.3.1.2  On the floor or on a raised base of less than 4" installation (R value for the 
hearth extension required) 
In the case where the fireplace is installed directly on the floor or on a raised base of less 
than 4", an R value for the hearth extension is required. In these case also, the joint 
between the hearth extension and the fireplace (E) must be protected by a non-
combustible material. For example, a sheet metal (not included). 
Note that the floor under of the fireplace should match or exceed the height of the floor 
protection. 
MINIMUM MEASUREMENT 
E 
2" (51 mm) 