Installation manual

34
TABLE 3 – LIST OF MANDATORY COMPONENTS
CHIMNEY
MANUFACTURER
MANDATORY COMPONENTS TYPE/BRAND
Selkirk
• Ventilated roof flashing.
• Must have rafter protectors at the roof level if
the chimney is enclosed at the attic level (see
section 5).
Ultra-Temp (UT),
Super Pro (SPR), Super
vent (JSC), Hart &
Cooley (TLC), Sure-
Temp (ST)
Security Chimney
• Rafter protector at the roof level if chimney is
enclosed at the attic level (see section 5).
• Requires insulated attic radiation shield unless
chimney is enclosed at the attic level.
ASHT +
Simpson Dura-Vent
• Ventilated roof flashing.
• Rafter protector at the roof level is chimney is
enclosed at the attic level (see section 5).
Dura Tech
ICC • Ventilated roof flashing. Excel 2100
American Metal • Chimney cannot be enclosed at the attic level. HS, HSS
NOTE: The floor protector in front of the fireplace must have a R value of 1.53 or greater.