TABLE 3 – LIST OF MANDATORY COMPONENTS 
CHIMNEY 
MANUFACTURER 
MANDATORY COMPONENTS  TYPE/BRAND 
Selkirk 
•  Ventilated roof flashing. 
•  Must have rafter protectors at the roof level if 
the chimney is enclosed at the attic level (see 
section 5). 
Ultra-Temp (UT), 
Super Pro (SPR), Super 
vent (JSC), Hart & 
Cooley (TLC), Sure-
Temp (ST) 
Security Chimney 
•  Rafter protector at the roof level if chimney is 
enclosed at the attic level (see section 5). 
•  Requires insulated attic radiation shield unless 
chimney is enclosed at the attic level. 
ASHT + 
Simpson Dura-Vent 
•  Ventilated roof flashing. 
•  Rafter protector at the roof level is chimney is 
enclosed at the attic level (see section 5). 
Dura Tech 
ICC  •  Ventilated roof flashing.  Excel 2100 
American Metal  •  Chimney cannot be enclosed at the attic level. HS, HSS 
 NOTE: The floor protector in front of the fireplace must have a R value of 1.53 or greater. 