Specifications

Solution 2.3 Installation and Operation Manual 31
CLEARANCES
(SINGLE WALL PIPE)
CANADA USA
A
15" (381 mm) 15" (381 mm))
B
17" (432 mm) 17" (432 mm)
C
10" (254 mm) 10" (254 mm)
D
18¾" (476 mm) 18¾" (476 mm)
E
27" (686 mm) 27" (686 mm)
F
20½" (521 mm) 20½" (521 mm)
K
48" (1220 mm) 48" (1220 mm)
L
84" (213 cm) 84" (213 cm)
CLEARANCES
(DOUBLE WALL PIPE)
CANADA USA
A
6" (152 mm) 6" (152 mm)
B
17" (432 mm) 17" (432 mm)
C
5" (127 mm) 5" (127 mm)
D
9¾" (248 mm) 9¾" (248 mm)
E
27" (686 mm) 27" (686 mm)
F
15½" (394 mm) 15½" (394 mm)
K
48" (1220 mm) 48" (1220 mm)
L
84" (213 cm) 84" (213 cm)
Clearances with ceiling (L) lowered to 76" (193 cm)
CLEARANCES
(SINGLE WALL PIPE)
CANADA USA
A
15" (381 mm)) 15" (381 mm))
B
17" (432 mm) 17" (432 mm)
C
14" (356 mm) 14" (356 mm)
D
18¾" (476 mm) 18¾" (476 mm)
E
27" (686 mm) 27" (686 mm)
F
24½" (622 mm) 24½" (622 mm)
K
48" (1220 mm) 48" (1220 mm)
L
76" (193 cm) 76" (193 cm)
CLEARANCES
(DOUBLE WALL PIPE)
CANADA USA
A
8" (203 mm) 8" (203 mm)
B
17" (432 mm) 17" (432 mm)
C
9" (229 mm) 9" (229 mm)
D
11¾" (298 mm) 11¾" (298 mm)
E
27" (686 mm) 27" (686 mm)
F
19½" (495 mm) 19½" (495 mm)
K
48" (1220 mm) 48" (1220 mm)
L
76" (193 cm) 76" (193 cm)
Clearances for mobile homes
MOBILE HOME CLEARANCES (DOUBLE WALL PIPE)
CANADA USA
A
14" (356 mm) 14" (356 mm)
B
19" (483 mm) 19" (483 mm)
C
13" (330 mm) 13" (330 mm)
D
17¾" (451 mm) 17¾" (451 mm)
E
29" (737 mm) 29" (737 mm)
F
23½" (597 mm) 23½" (597 mm)
K
48" (1220 mm) 48" (1220 mm)
L
84" (213 cm) 84" (213 cm)