Owner`s manual

17
MINIMUM MASONRY OPENING
Solution 1.8-I Solution 2.3-I
J
21 1/4” (540 mm) 23 3/8” (594 mm)
K
28 7/8” (733 mm) 28 7/8” (733 mm)
L
13 1/8” (333 mm) 15 3/4”(400 mm)
CLEARANCES
Solution 1.8-I Solution 2.3-I
F
13’’ (330 mm) 13’’ (330 mm)
G
10’’ (254 mm) 10’’ (254 mm)
H
22’’ (559 mm) 22’’ (559 mm)
I
29’’ (737 mm) 29’’ (737 mm)
FLOOR PROTECTOR
CANADA USA
B
18’’ (457 mm) – Note1 16’’ (406 mm) – Note 1
M
8’’ (203 mm) N/A (Canada only)
N
N/A (USA only) 8’’ (203 mm)
* For a 6" (152 mm) shelf. See Table SHELF POSITIONING (Section 2.5) for other shelf dimensions.
Note 1: From door opening. The depth of a non-combustible shelf in from of the insert is included in
the calculation of the floor protector’s dimensions.
IMPORTANT: The masonry hearth should be at least 4 inches (102 mm) higher than the combustible
floor in front of it. If the hearth elevation is lower than 4 inches, the non-combustible floor protector in
front of the insert should have an R value equal or greater than 1.00.