Specifications

6
3000775 12.12
3.4 Single Fan on Brick Chimney
Theinstallationprocedureisthesameforroundandsquareues.
Ifaclayuelinerisinstalledandextendsbeyondthechimney,
cut it back so it extends no more than 1/2 inch above the chimney
crown.
Apply a bead of high-temperature silicone around the edges
oftheuetile.Placethefanovertheueandmakesurethefan
is completely sealed to the clay tile.
Open the top of the fan housing and secure with anchor bolts
through the pre-drilled mounting holes.
3.5 Side-Wall Mounting the Fan
Makesuretheventterminatesushwiththewall.Insertthesteel
chimney adapter (SCA) and secure it safely to the wall.
Sealaroundtheedgesoftheadapterange.
Mark the locations of the wall anchors and predrill holes for them.
Turn the fan upside-down and apply a bead of high-temperature
silicone on the base of the housing, close to the outer edge.
Orient the fan so the motor terminal box is pointed upwards. The
hinges on the housing should be on the left-hand side of the
installer as shown in Fig. 6.
Open the fan and secure it onto the adapter with wall anchors,
through the predrilled holes in the bottom. Make sure the conduit
is located on one of the sides, never on the upside or downside.
Seal around the fan base to make sure it is watertight and no
water can slip in between the fan and the adapter.
Do not block the (4) drain holes.
Do not side-wall mount the RSV450.
Caution: Never place hands or ngers on top of
fan base when closing
Fig. 5
Fig. 6