Specifications
45
T
he ADC150 Control, for gas appliances, monitors the draft and
will maintain the proper draft set-point by modulating the chimney
fan speed whenever needed. When the user turns the replace or
appliance off, the control leaves the damper open until all residual
combustion products have been exhausted.
Use the EFC211 control with wood-red heating appliances to
control the proper speed of the chimney fan. The EFC211 fan
control features an audible and visual alarm.
ADC150 Draft Control
PDS1 Proven Draft Switch
XTP2 Pressure Sensor
FSC Fan Speed Control
Use the PDS1 Proven Draft Switch to provide
protection from insufcient draft. When there is an unsafe draft, the
switch shuts down the gas-red appliance or replace.
The XTP2 is a pressure transducer that monitors the pressure at
an appliance outlet, in an exhaust duct or in a room. The ADC 150
control box communicates with the XTP2, and the readings are
used to determine whether to increase or decrease the fan speed.
ENERVEX Fan Speed Control FSC is used in conjunction with all
single-phased chimney fans. The fan speed control is specially
engineered to provide variable speed control of split capacitor
motors. The control is accomplished by reducing the line voltage
to the motor thereby using only the energy required to maintain the
desired volume of air ow (fan speed).
EFC 211 Control