Specifications
31
6.7 Mechanical Draft System for a Gas-red
Fireplace with multiple ues with Safety
System per NFPA54/IFGC
Application
This is used in the same situations as System 5,
but where multiple fans are required to handle the
exhaust volume. It is a typical installation for large
replaces where a single ue cannot handle the
amount of exhaust gases generated.
This is a simple form of installation when used with
a gas-red replace. The set-up can be used with
virtually any type of gas-red heating appliance.
*For one fan serving two ues please refer to section
6.5 as the wiring diagram is identical. A special
plenum box may be required.
Sequence of Operation
1. Turn the fan speed control on by turning the
knob clockwise. A “click” indicates the control
is turned on. Adjust the knob to the desired
speed.
2. Start the re by pushing the igniter or other
means used to start the re.
3. Fine-tune the fan speed setting so spillage from
the replace opening can not be detected.
Hot, moist heat rising from the top of the replace
is an indication of spillage. For better detection,
hold a mirror over the replace opening
4. In case of mechanical or electrical fan failure, the
proven draft switch will disconnect the ow of fuel
to the replace or the gas logs.
5. Once the proper draft has been established in
the chimney, the proven draft switch will close to
allow the ow of fuel.
6. When the fan is turned off, the proven draft switch
will open and automatically turn off the ow of
gas.
+/
_
FSC
Fan Speed Control
Chimney
Fans
Chimney
Probe
Chimney
Probe
PDS
Proven Draft
Switch
RED
WHITE
BLACK
GREEN
FAN
MOTOR
120/1/60
NOTES:
THE DISCONNECT MEANS AND CIRCUIT PROTECTION ARE TO
BE PROVIDED BY THE INSTALLER OF THIS DEVICE
1
2
All wiring must be in
flexible or rigid metal
conduit
LEGEND:
24 VAc
120 VAC
WEATHERPROOF BOX
N
FAN SPEED
CONTROL
ORANGE
RED
WHITE
BLACK
GREEN
FAN
MOTOR
WEATHERPROOF BOX
ORANGE
WEATHERPROOF
BOX
L
24V GAS VALVE
COM
TR
HOT
TH
PROVEN DRAFT
SWITCH
24 VAC
System 7
Gas-Fired Fireplace