Specifications
29
System 5
Gas-Fired Fireplace
+/
_
FSC
Fan Speed Control
6.5 Mechanical Draft System for a Gas-Fired
Fireplace with a single ue with Safety
System per NFPA54/IFGC
Application
This is the simplest form of installation when used
with a gas replace. The set-up can be used with
virtually any type of gas-red heating appliance.
Sequence of Operation
1. Turn the fan speed control on by turning the
knob clockwise. A “click” indicates the control
is turned on. Adjust the knob to the desired
speed.
2. Start the re by pushing the igniter or other
means used to start the re.
3. Fine-tune the fan speed setting so spillage from
the replace opening can not be detected.
Hot, moist heat rising from the top of the replace
is an indication of spillage. For better detection,
hold a mirror over the replace opening
4. In case of mechanical or electrical fan failure, the
proven draft switch will disconnect the ow of fuel
to the replace or the gas logs.
5. Once the proper draft has been established in
the chimney, the proven draft switch will close to
allow the ow of fuel.
6. When the fan is turned off, the proven draft switch
will open and automatically turn off the ow of
gas.
24V GAS VALVE
COM
TR
HOT
TH
PROVEN DRAFT
SWITCH
RED
WHITE
BLACK
GREEN
FAN
MOTOR
120/1/60
24 VAC
NOTES:
THE DISCONNECT MEANS AND CIRCUIT PROTECTION ARE TO
BE PROVIDED BY THE INSTALLER OF THIS DEVICE
1
All wiring must be in
flexible or rigid metal
conduit
LEGEND:
24 VAC
120 VAC
WEATHERPROOF BOX
N
L
FAN SPEED
CONTROL
ORANGE