Owner`s manual

VENTING REQUIREMENTS
8External Roof-mounted Power Vent System EuropeanHome.com
The venting for a power vented replace is installed in the same manner as a non-power vented replace. The dierence between
the two types of venting is in the allowable distances. In all installations of this power vent system the following MUST be
observed:
With the IPVS, the maximum allowable horizontal or vertical length of the replace venting is 82 feet (25 meters.) This distance
is measured between the top of the replace and the base of the termination.
• Only M&G DuraVent®-brand direct vent components are approved for use with the IPVS.
The venting may have no more than ve 90-degree elbows or ten 45-degree elbows or a combination not exceeding 450
degrees of elbow.
The venting may turn down but it must not go below the base of the replace. See illustrations, below.
The joints of each venting section must be properly sealed with approved tape or caulk.
34’
42’
Figure 2. Conguration is Permitted - Length and
Elbow Count Within Limits