Owner`s manual

OPERATING the SYSTEM
External Roof-mounted Power Vent System EuropeanHome.com20
TURNING THE SYSTEM ON
Turn the PV-ES-PLS-WHT-02 switch to the ON position. The fan will provide negative pressure (draft). Once the fan has
generated enough draft to reach the draft set-point, the PV-ES-PLS-WHT-02 indicator lamp will light and the PV-GS-SGV-01
valve will open. The gas replace is now ready for normal operation via the E4-SA-WS-80 wall switch or the remote control.
The E4-SA-WS-80 wall switch has three buttons on it; On/O, UP ame, DOWN ame. Press the On/O button to begin the
start-up sequence. After the main burner has lit the UP ame or DOWN ame button may be used as desired. Note that on
multiple burner models the secondary burner(s) cannot be controlled by the wall switch, the remote control must be used.
TURNING THE SYSTEM OFF
First, turn the gas replace o using the either E4-SA-WS-80 wall switch or the remote control then turn the PV-ES-PLS-
WHT-02 switch OFF. The indicator lamp and the gas both turn o.
Note: The system shuts o the appliance completely if there is no change in the ame height
for 5 days.
Setting °C/24 Hour or °F/12 Hour Clock.
Press OFF andÈto toggle between °F/12 hr and °C/24 hr clock.
Setting the time.
Simultaneously press theÈand
Çbuttons, the display now ashes.
PressÇto set the hour andÈto set the minute.
Press OFF to return to manual mode.
Igniting the Appliance.
On the remote control, simultaneously press and hold the OFF andÇbuttons.
An acoustic signal indicates that the start sequence has begun.
The electronic system then checks that the main gas is owing and ignites the main burner;
this may take up to 20 seconds.
NOTE: During start-up, the MANUAL knob on the gas valve cannot be in the MAN position.
Changing the Mode of Operation.
Briey pressing the SET button changes the mode of operation in the following order:
Man - Temp - Temp - Timer - back to Man
UP
DOWN
USING THE REMOTE CONTROL ELECTRONIC IGNITION SYSTEM
OFF
SET
Figure 10.
Remote Control